Maintenance Of Automatic Hard Capsule Filling Machine

Apr 09, 2020

Maintenance of automatic hard capsule filling machine

 

(1) when the normal working time of the capsule filling machine is long, the parts that are in direct contact with the medicine should be cleaned regularly, and the parts should be cleaned when the medicine batch is changed or the time of disuse is long.

 

(2) lubricating oil (grease) should be added to the transmission mechanism under the working table of automatic capsule filling machine to reduce the wear of moving parts.

 

(3) the oil quantity of the main drive reducer of the automatic capsule filling machine should be checked once a month, refueling should be carried out in time if insufficient, and lubricating oil should be replaced once every half a year; The lubricating oil should be changed once for every 3000h of operation of the rotary table station dividing box, generally using 90# oil.

 

(4) automatic capsule machine safety clutch is up when the machine is overload protection, when the normal load should not slip of the clutch, but due to the long time use also may appear the phenomenon of slippage, when the slippage phenomenon in a normal use, clutch round nut can be tighten, ensure the machine run properly in order to achieve the purpose of protection.

 

(5) the vacuum separator of the vacuum system of the capsule filling machine mainly plays the role of inhaling the capsule into the upper and lower modules and separating the cap and body in the hard capsule filling. If the capsule cannot be separated from the cap and body, the subsequent filling cannot be carried out. Every time the rotary table of the machine runs 1 station, the machine spindle rotates for 1 cycle, and the vacuum separator moves up and down 1 time under the action of the CAM. If the separation of capsule cap and body is not smooth, the gap between the upper plane of the vacuum separator and the lower plane of the lower module should be checked. If the gap is too large, the vacuum degree of the vacuum system will not reach the vacuum degree required by the separation of cap and body (around 0.05mpa). When need to adjust the position of the vacuum separator, turn the main motor shaft by the handle, to rise to make the vacuum separator zui high position, loosen the adjustment of the machine mesa falls at the ends of the rod lock nut (a left-handed nut, a right-handed nut), and then turn adjusting screw to adjust the height of the vacuum separator, then lock nut and turn the main motor shaft test by the handle until it is right. The vacuum degree can be read on the vacuum meter on the operation panel of the machine. If the vacuum degree is too high, the vacuum degree control valve can be opened appropriately. If the vacuum degree is too low, the vacuum degree control valve can be closed or closed. The filter of the vacuum system should be opened regularly to clean up the blocked dirt to ensure that the vacuum system has enough vacuum.

 

(6) the transmission chain of small capsule filler should be checked once a week, and an appropriate amount of grease should be added. It is necessary to tighten it again. When the chain is too loose and needs to be tightened again, the tensioning wheel should be moved to adjust, but the chain cannot be opened and the chain cannot be separated from the sprocket, so as not to disturb the movement order of the entire mechanism, to prevent the occurrence of mechanism movement interference.